An interface that negotiates badly produces a network that works and is inexplicably slow. The counters tell you in seconds.

What the link thinks it is

ethtool eno1

Check three lines: Speed, Duplex and Auto-negotiation. You want the expected speed, Full duplex, and auto-negotiation on at both ends.

Never hard-set the speed on one side only. A fixed setting on your side against auto-negotiation on the switch produces a half-duplex link: it works, it passes small packets, and throughput collapses under load with late collisions in the counters. It is the classic slow-network-nobody-can-explain.

The counters

ip -s link show eno1

ethtool -S eno1 | grep -iE 'err|drop|crc|discard'

RX errors or CRC errors
Frames arriving damaged. Cabling, an optic, or a port. Not something you can configure away.
RX dropped
Often the host, not the wire — ring buffers or a saturated core. See network cards and offloads.
TX errors or carrier errors
The link is flapping or the far end is unhappy.
Collisions, on a modern link
Should be zero. Anything else means half duplex somewhere.

What matters is whether they are increasing. A handful since boot is nothing; a hundred an hour is a fault.

Optics

On fibre, read the module directly:

ethtool -m eno1

Look at the transmit and receive power against the module's own thresholds. Receive power drifting towards the low warning is a dirty connector or a failing optic, and it shows up as CRC errors long before the link drops.

Watch for flapping

journalctl -k | grep -iE 'link (up|down)'

A link that goes down and up repeatedly is worse than one that stays down, because routing and bonding keep reconverging. On a bond, check both members are really up:

cat /proc/net/bonding/bond0

See bonding and LACP — a bond quietly running on one member is a common and invisible state.

When to open a ticket

Errors on the interface are not a tuning matter. Cabling, optics and switch ports are our hardware. Send us:

  1. The machine identifier
  2. ethtool eno1 and ethtool -S eno1 output
  3. ip -s link, ideally twice a few minutes apart so we can see the rate
  4. Whether it is constant or follows load

We check the switch side, where the same counters exist from the other direction. A cable or an optic is replaced from stock in Amsterdam — see hardware failure.

Rule out the host first

If the counters are clean and it is still slow, the problem is above the interface: see speed testing, TCP tuning and latency and bandwidth.


Still stuck? Mail support@novogara.com — an engineer answers, at any hour. Back to the knowledge base